Selection of optimal separator and accessories
Machine cooling with emulsion
Machining specification |
Laminated filter as guard for chips filter |
Chips filter stainless fabric |
Chips filter aluminum fabric |
Laminated filter |
Filter with filtration class F7 |
Filter with filtration class E11 HEPA |
Electrostatic filter no. 1 |
Electrostatic filter no. 2 |
Classic machining |
Required at position I | Required at position III | unsuitable | unsuitable | ||||
Machining with high pressure cooling over 40 bars |
Required at position I | Required at position II | Recommended at position III | unsuitable | unsuitable | |||
Machining in continuous operation with long maintenance intervals |
Recommended at position I | Required at position II | Required at position III | unsuitable | unsuitable | |||
During machining separation of emulsion to emulsion oil and water occurs, i.e. thanks to hard water |
Required at position I | Required at position II | Recommended at position III | unsuitable | unsuitable | |||
During machining fine dust particles are created, i.e. machining of stainless steel, cast iron |
Required at position I | Required at position II | Recommended at position III | unsuitable | unsuitable | |||
During machining large amounts of smoke are created, i.e. machining of stainless steel or other hard to machine materials |
Required at position I | Required at position II | Recommended at position III | unsuitable | unsuitable | |||
Machining with high demand for air cleanness, i.e. machining in clean room |
Required at position I | Required at position II | Recommended at position III | unsuitable | unsuitable |
For use on the machine we recommend using separators BETA (with two-staged motor)
or GAMA (with motor controlled by potentiometer) with smooth regulation of power
Machine cooling with oil mist (MQL cooling)
Machining specification |
Laminated filter as guard for chips filter |
Chips filter stainless fabric |
Chips filter aluminum fabric |
Laminated filter |
Filter with filtration class F7 |
Filter with filtration class E11 HEPA |
Electrostatic filter no. 1 |
Electrostatic filter no. 2 |
Classic machining |
Required at position I | Required at position II | Recommended at position III | unsuitable | unsuitable | |||
Machining in continuous operation with long maintenance intervals |
Required at position I | Required at position II | Recommended at position III | unsuitable | unsuitable | |||
During machining large amounts of smoke are created, i.e. machining of stainless steel or other hard to machine materials |
Required at position II | Required at position III | Recommended at position III | unsuitable | unsuitable | |||
Machining with high demand for air cleanness, i.e. machining in clean room |
Required at position I | Required at position II | Recommended at position III | unsuitable | unsuitable |
For use on the machine we recommend using separators BETA (with two-staged motor)
or GAMA (with motor controlled by potentiometer) with smooth regulation of power.
Machine cooling with cutting oil
Machining specification |
Laminated filter as guard for chips filter |
Chips filter stainless fabric |
Chips filter aluminum fabric |
Laminated filter |
Filter with filtration class F7 |
Filter with filtration class E11 HEPA |
Electrostatic filter no. 1 |
Electrostatic filter no. 2 |
Classic machining |
Required at position I | Required at position II | Unsuitable, short service life | Required at position III | Recommended at position IV | |||
Machining with high pressure cooling over 40 bars |
Required at position I | Required at position II | Unsuitable, short service life | Required at position III | Recommended at position IV | |||
Machining in continuous operation with long maintenance intervals |
Required at position II | Required at position III | Unsuitable, short service life | Required at position III | Recommended at position IV | |||
During machining fine dust particles are created, i.e. machining of stainless steel, cast iron |
Required at position I | Required at position II | Unsuitable, short service life | Required at position III | Recommended at position IV | |||
During machining large amounts of smoke are created, i.e. machining of stainless steel or other hard to machine materials |
Required at position I | Required at position II | Unsuitable, short service life | Required at position III | Required at position IV | |||
Machining with high demand for air cleanness, i.e. machining in clean room |
Required at position I | Required at position II | Unsuitable, short service life | Required at position III | Required at position IV |
For use on the machine we recommend using separators DELTA.
Machines without cooling – dry machining
Machining specification |
Laminated filter as guard for chips filter |
Chips filter stainless fabric |
Chips filter aluminum fabric |
Laminated filter |
Filter with filtration class F7 |
Filter with filtration class E11 HEPA |
Electrostatic filter no. 1 |
Electrostatic filter no. 2 |
Classic machining |
Required at position I | Required at position II | Required at position III |
For use on the machine we recommend using separators BETA (with two-staged motor)
or GAMA (with motor controlled by potentiometer) with smooth regulation of power.
Filters only intercept dust particles using filtration lamellas, they are not separated.
Filters require to be changed when full, in case of chips filter cleaned.
Note:
Filters class F2 and E11 are not cleanable. It is required to be changed in case of pollution.